Garage
Garage-door opener with an impulse output and at least one contact sensor for state feedback. Labelled Garage in the Web Interface.
Setup
| Field | Description |
|---|---|
| Sensors | At least one is required. The input modal asks Close or Open instead of Switch / Momentary, depending on what your reed contact signals when the door is in that position. |
| Outputs | Pick Single relay control (one impulse output that triggers the opener) or One relay for open, another for close (two separate impulse outputs). |
| Runtime | Total open or close time in seconds. The SmartCore uses this together with the sensors to compute current state. |
| Garage has a stop state | Check this if your opener cycles OPENING, STOPPED, CLOSING with each impulse instead of just OPEN and CLOSED. |
Sensor input modal
| Setting | Description |
|---|---|
| Close | Pick this if your reed contact reports an active signal when the door is closed. |
| Open | Pick this if your reed contact reports an active signal when the door is open. |
| Inverted | Reverses the above reading. Use if the sensor reports the opposite of what you expect. |